update HA interface source files
This commit is contained in:
@@ -1,55 +1,85 @@
|
||||
"""Constants used by the koolnova-bms component."""
|
||||
|
||||
from homeassistant.const import CONF_ICON, CONF_NAME, CONF_TYPE
|
||||
from homeassistant.components.climate.const import (
|
||||
HVAC_MODE_COOL,
|
||||
HVAC_MODE_HEAT,
|
||||
HVAC_MODE_DRY,
|
||||
HVAC_MODE_FAN_ONLY,
|
||||
HVAC_MODE_AUTO,
|
||||
ClimateEntityFeature,
|
||||
HVACMode,
|
||||
FAN_AUTO,
|
||||
)
|
||||
|
||||
DOMAIN = "koolnova_bms"
|
||||
DEVICES = "wf-rac-devices"
|
||||
|
||||
NUM_ZONES = 16
|
||||
CONF_OPERATOR_ID = "operator_id"
|
||||
CONF_AIRCO_ID = "airco_id"
|
||||
ATTR_DEVICE_ID = "device_id"
|
||||
ATTR_CONNECTED_ACCOUNTS = "connected_accounts"
|
||||
|
||||
REG_PER_ZONE = 4
|
||||
REG_ENABLED = 1
|
||||
REG_MODE = 2
|
||||
REG_TARGET_TEMP = 3
|
||||
REG_CURRENT_TEMP = 4
|
||||
ATTR_INSIDE_TEMPERATURE = "inside_temperature"
|
||||
|
||||
REG_AIRFLOW = 65
|
||||
REG_AC_TARGET_TEMP = 69
|
||||
REG_AC_TARGET_FAN_MODE = 73
|
||||
REG_SERIAL_CONFIG = 77
|
||||
REG_SLAVE_ID = 78
|
||||
REG_EFFICIENCY = 79
|
||||
REG_SYSTEM_ENABLED = 81
|
||||
REG_SYS_KN_MODE = 82
|
||||
SENSOR_TYPE_TEMPERATURE = "temperature"
|
||||
|
||||
FIRST_ZONE_REGISTER = REG_ENABLED
|
||||
TOTAL_ZONE_REGISTERS = NUM_ZONES * REG_PER_ZONE
|
||||
FIRST_SYS_REGISTER = REG_AIRFLOW
|
||||
TOTAL_SYS_REGISTERS = 18
|
||||
SENSOR_TYPES = {
|
||||
ATTR_INSIDE_TEMPERATURE: {
|
||||
CONF_NAME: "Inside Temperature",
|
||||
CONF_ICON: "mdi:thermometer",
|
||||
CONF_TYPE: SENSOR_TYPE_TEMPERATURE,
|
||||
},
|
||||
}
|
||||
|
||||
FAN_OFF = 0
|
||||
FAN_LOW = 1
|
||||
FAN_MED = 2
|
||||
FAN_HIGH = 3
|
||||
FAN_AUTO = 4
|
||||
SUPPORT_FLAGS = (
|
||||
ClimateEntityFeature.TARGET_TEMPERATURE
|
||||
| ClimateEntityFeature.FAN_MODE
|
||||
)
|
||||
|
||||
MODE_AIR_COOLING = 0x01
|
||||
MODE_AIR_HEATING = 0x02
|
||||
MODE_UNDERFLOOR_HEATING = 0x04
|
||||
MODE_UNDERFLOOR_AIR_COOLING = 0x05
|
||||
MODE_UNDERFLOOR_AIR_HEATING = 0x06
|
||||
SUPPORTED_HVAC_MODES = [
|
||||
HVACMode.OFF,
|
||||
HVACMode.AUTO,
|
||||
HVACMode.COOL,
|
||||
HVACMode.DRY,
|
||||
HVACMode.HEAT,
|
||||
HVACMode.FAN_ONLY,
|
||||
]
|
||||
|
||||
HOLD_MODE_UNDERFLOOR_ONLY = "underfloor"
|
||||
HOLD_MODE_FAN_ONLY = "fan"
|
||||
HOLD_MODE_UNDERFLOOR_AND_FAN = "underfloor and fan"
|
||||
HVAC_TRANSLATION = {
|
||||
HVAC_MODE_AUTO: 0,
|
||||
HVAC_MODE_COOL: 1,
|
||||
HVAC_MODE_HEAT: 2,
|
||||
HVAC_MODE_FAN_ONLY: 3,
|
||||
HVAC_MODE_DRY: 4,
|
||||
}
|
||||
|
||||
HVAC_MODE_OFF = "off"
|
||||
HVAC_MODE_COOL = "cool"
|
||||
HVAC_MODE_HEAT = "heat"
|
||||
FAN_MODE_1 = "1 Lowest"
|
||||
FAN_MODE_2 = "2 Low"
|
||||
FAN_MODE_3 = "3 High"
|
||||
FAN_MODE_4 = "4 Highest"
|
||||
|
||||
ACMACHINES = 4
|
||||
FAN_MODE_TRANSLATION = {
|
||||
FAN_AUTO: 0,
|
||||
FAN_MODE_1: 1,
|
||||
FAN_MODE_2: 2,
|
||||
FAN_MODE_3: 3,
|
||||
FAN_MODE_4: 4,
|
||||
}
|
||||
|
||||
AC1 = 1
|
||||
AC2 = 2
|
||||
AC3 = 3
|
||||
AC4 = 4
|
||||
SUPPORTED_FAN_MODES = [
|
||||
FAN_AUTO,
|
||||
FAN_MODE_1,
|
||||
FAN_MODE_2,
|
||||
FAN_MODE_3,
|
||||
FAN_MODE_4,
|
||||
]
|
||||
|
||||
HA_COMPONENT_SENSOR = "sensor"
|
||||
HA_COMPONENT_CLIMATE = "climate"
|
||||
OPERATION_LIST = {
|
||||
# HVAC_MODE_OFF: "Off",
|
||||
HVAC_MODE_HEAT: "Heat",
|
||||
HVAC_MODE_COOL: "Cool",
|
||||
HVAC_MODE_AUTO: "Auto",
|
||||
HVAC_MODE_DRY: "Dry",
|
||||
HVAC_MODE_FAN_ONLY: "Fan",
|
||||
}
|
||||
|
||||
Reference in New Issue