Files
koolnova2mqtt/kn/sys.go
2020-12-16 00:08:42 +01:00

135 lines
2.8 KiB
Go

package kn
import "errors"
type SysConfig struct {
Watcher Watcher
}
type Sys struct {
SysConfig
OnACAirflowChange func(ac ACMachine)
OnACTargetTempChange func(ac ACMachine)
OnACTargetFanModeChange func(ac ACMachine)
OnEfficiencyChange func()
OnSystemEnabledChange func()
OnKnModeChange func()
}
var ErrUnknownSerialConfig = errors.New("Uknown serial configuration")
func NewSys(config *SysConfig) *Sys {
s := &Sys{
SysConfig: *config,
}
for n := byte(0); n < ACMachines; n++ {
func(ac ACMachine) {
s.Watcher.RegisterCallback(uint16(REG_AIRFLOW+ac-1), func(address uint16) {
if s.OnACAirflowChange != nil {
s.OnACAirflowChange(ac)
}
})
s.Watcher.RegisterCallback(uint16(REG_AC_TARGET_TEMP+ac-1), func(address uint16) {
if s.OnACTargetTempChange != nil {
s.OnACTargetTempChange(ac)
}
})
s.Watcher.RegisterCallback(uint16(REG_AC_TARGET_FAN_MODE+ac-1), func(address uint16) {
if s.OnACTargetFanModeChange != nil {
s.OnACTargetFanModeChange(ac)
}
})
}(ACMachine(n + 1))
}
s.Watcher.RegisterCallback(REG_EFFICIENCY, func(address uint16) {
if s.OnEfficiencyChange != nil {
s.OnEfficiencyChange()
}
})
s.Watcher.RegisterCallback(REG_SYSTEM_ENABLED, func(address uint16) {
if s.OnSystemEnabledChange != nil {
s.OnSystemEnabledChange()
}
})
s.Watcher.RegisterCallback(REG_SYS_KN_MODE, func(address uint16) {
if s.OnKnModeChange != nil {
s.OnKnModeChange()
}
})
return s
}
func (s *Sys) ReadRegister(n int) int {
r := s.Watcher.ReadRegister(uint16(n))
return int(r[1])
}
func (s *Sys) WriteRegister(n int, value uint16) error {
return s.Watcher.WriteRegister(uint16(n), value)
}
func (s *Sys) GetAirflow(ac ACMachine) int {
r := s.ReadRegister(REG_AIRFLOW + int(ac) - 1)
return r
}
func (s *Sys) GetMachineTargetTemp(ac ACMachine) float32 {
r := s.ReadRegister(REG_AC_TARGET_TEMP + int(ac) - 1)
return reg2temp(uint16(r))
}
func (s *Sys) GetTargetFanMode(ac ACMachine) FanMode {
r := s.ReadRegister(REG_AC_TARGET_FAN_MODE + int(ac) - 1)
return FanMode(r)
}
func (s *Sys) GetBaudRate() int {
r := s.ReadRegister(REG_SERIAL_CONFIG)
switch r {
case 2, 6:
return 9600
case 3, 7:
return 19200
}
return 0
}
func (s *Sys) GetParity() string {
r := s.ReadRegister(REG_SERIAL_CONFIG)
switch r {
case 2, 3:
return "even"
case 6, 7:
return "none"
}
return "unknown"
}
func (s *Sys) GetSlaveID() int {
r := s.ReadRegister(REG_SLAVE_ID)
return r
}
func (s *Sys) GetEfficiency() int {
r := s.ReadRegister(REG_EFFICIENCY)
return r
}
func (s *Sys) GetSystemEnabled() bool {
r := s.ReadRegister(REG_SYSTEM_ENABLED)
return r != 0
}
func (s *Sys) GetSystemKNMode() KnMode {
r := s.ReadRegister(REG_SYS_KN_MODE)
return KnMode(r)
}
func (s *Sys) SetSystemKNMode(knMode KnMode) error {
return s.WriteRegister(REG_SYS_KN_MODE, uint16(knMode))
}