update readme
This commit is contained in:
45
README.md
45
README.md
@@ -1,7 +1,7 @@
|
||||
# koolnova-BMS-Integration
|
||||
|
||||
[](https://github.com/hacs/integration)
|
||||
[](https://git.nas.benserv.fr/vincent/koolnova-BMS-Integration/raw/branch/main/LICENSE)
|
||||
[](https://github.com/koolnova-BMS-Integration/blob/main/LICENSE)
|
||||
[](https://github.com/sinseman44/koolnova-BMS-Integration/releases)
|
||||
[](https://github.com/sinseman44/koolnova-BMS-Integration/releases)
|
||||
[](https://my.home-assistant.io/redirect/hacs_repository/?owner=sinseman44&repository=koolnova-BMS-Integration&category=integration)
|
||||
@@ -89,7 +89,48 @@ The area configuration ends with no new area.<br />
|
||||
|
||||
# Features
|
||||
|
||||
TODO
|
||||
- Integrates local API to read/write Modbus koolnova registers
|
||||
- Provides `climate` for each area, `sensor`, `select` and `switch`
|
||||
|
||||
## Climate
|
||||
|
||||
The following parameters can be controlled for the `climate` platform entities:
|
||||
- Power
|
||||
- Target temperature (celcius)
|
||||
- Operation mode (HVAC mode)
|
||||
|
||||
## Sensor (Diagnostic)
|
||||
|
||||
The following attributes are available for diagnostic `sensor` platform entities:
|
||||
- Modbus serial (Device, Address, port, ...)
|
||||
- Target temperature (celcius) and throughput for each engine (maximum 4):
|
||||
- Target temperature: Min: 15°C -> Max: 30°C
|
||||
- Troughput: int value between 0 (engine stopped) to 15 (maximum troughput)
|
||||
|
||||
## Select
|
||||
|
||||
The following parameters can be controlled for the `select` platform entities:
|
||||
- Global operation mode (HVAC mode)
|
||||
- cold
|
||||
- heat
|
||||
- heating floor
|
||||
- refreshing floor and refreshing air
|
||||
- heating floor and heating air
|
||||
|
||||
- Global efficiency defined the balance point between efficiency and speed of the area system.
|
||||
- Lower: the set temperature is reached sooner
|
||||
- Higher: better efficiency
|
||||
|
||||
- Engine state: int value which represents the flow programming of the system engines
|
||||
- 1: Manual minimum
|
||||
- 2: Manual medium
|
||||
- 3: Manual high
|
||||
- 4: Automatic
|
||||
|
||||
## Switch
|
||||
|
||||
The following parameter can be controlled for the `switch` platform entitie:
|
||||
- Global HVAC State (stopped or running)
|
||||
|
||||
# Debugging
|
||||
|
||||
|
||||
Reference in New Issue
Block a user